Question1: A technician is setting up a 10 GbE PS Series group SAN using 10 GbE switches in a converged iSCSI network.What is recommended to set up this group to ensure good performance and delivery?
Question2: A technician needs to install PSM4110 storage arrays in an M1000e blade enclosure.What is the maximum number of PSM4110 storage arrays that can be installed?
Question3: An engineer is creating snapshot schedules for a volume to protect against data corruption. Snapshots must be taken both hourly and nightly. Each schedule is configured for a max keep of 10. Snapshot borrowing is enabled. The default snapshot schedule has NOT been disabled.What should be the expected max number of snapshots for this volume?
Question4: A customer is deploying a new PS Series Storage array that will hold business critical application data.Which RAID policy selected through the Group Manager provides the greatest level of data protection?
Question5: Refer to the exhibit.An installer has cabled an array as shown.Which changes must the installer make to cable the array per the recommended configuration?
Question6: The volume in-use warning slider is visible only when which condition exists?
Question7: An installer needs to deploy a PSM4110 array in a new blade chassis. iSCSI switches are installed in slots B1 and B2. The array is installed in the chassis.Which other connections are required for server blades to access storage?
Question8: According to Dell recommendations, when should a firmware update be performed on a PS Series group?
Question9: An alarm is triggered within vCenter. The alarm indicates that free spaces is about to run out on a 10 TB datastore that resides on a PS Series array. The Dell Virtual Storage Manager (VSM) is deployed.Which two workflows within the VSM should be used to fix this problem? (Choose two.)
Question10: A customer buys two PS Series arrays to store data for the database servers. One array has 15K RPM disks configured as RAID 10, and the other array has 10K RPM disks configured as RAID 6. This system was chosen to meet the need to data capacity and a very high anticipated level of IOPs.The customer reports that database servers run business critical applications. Performance is a priority for these databases. A large data warehouse holds historical data from the business used to mine data.Which two configurations provide the fastest performance to meet the customer requirements? (Choose two.)
Question11: A customer needs a full, permanent, point-in-time, local copy of the data.Which Dell PS Series feature should be configured to meet the requirement?
Question12: A storage administrator has a two-member PS Series group that consists of a PS6510 and a PS6210 series array. The storage administrator wants to update the version of firmware via the Group Manager for both arrays.After extracting the downloaded firmware zip file, storage administrator discovers there are two files titled kit_64_Vxxxxxxx.tgz & kit_Vxxxxxxx.tgz.Which two firmware kits should be applied to the PS Series arrays? (Choose two.)
Question13: An administrator recently deploys the Dell Virtual Storage Manager (VSM) version 4.x. Several minutes after the Deploy OVF Template task completes, the VSM icon does NOT appear in the vSphere Web Client.What is preventing the appearance of the VSM icon?
Question14: A customer shares an iSCSI network with other traffic.What is the Dell-recommended approach to maintain acceptable performance?
Question15: Refer to the exhibit.An installer configures one Dell PS Series group in Phoenix and one in New York as shown. Only one-way replication from Phoenix to New York is required.Which two configuration items are incorrect? (Choose two.)
Question16: A customer orders a PS6610E storage array.What does the "E" in the model number indicate?
Question17: Which two cable types are appropriate to cable a 10 Gb PS Series array excluding the PS6010 and PS6510? (Choose two.)
Question18: A customer needs to control the location of data securely. Due to regulatory requirements, the customer's marketing department and engineering department must keep their files physically separate. User file data has no restrictions, and can be mixed with engineering and/or marketing data. Due to limited IT stuff, the customer needs the simplest solution possible to install and maintain.Which solution meets the customer requirements?
Question19: Which Dell PowerEdge server slot does an HBA card use?
Question20: A customer has 10 volumes within a storage group. Each volume has 14 hosts granted access via separate basic access point lists. The customer needs to bring online an additional three systems that require the same access. The customer needs to add the new servers and grant access to the 10 storage group volumes according to Dell-recommended best practices.Which workflow should the customer follow to meet the requirements?
Question21: A customer needs to use a Disaster Recovery (DR) site for replication. The customer provides the following information:- Volumes to replicate: 1- Volume size (total): 1.5 TB- Total data set size: 1 TB- Change rate: Averages 10% per hourAfter setting up replication, the customer monitors the results. The volume replicates successfully only about 75% the time. The remaining time, no data is replicated. Although some replications have failed, no user intervention has occurred. The replication works on subsequent intervals.Which action should be taken to ensure reliable replication?
Question22: A customer has a Windows 2012 VM that runs on a VMware ESXi 5.5. server. The volumes for Exchange used by the VM will come from the Dell PS Series array. A requirement is application-consistent snapshots of that Exchange database using HIT/Microsoft.Which VMware ESXi storage methodology should be used to meet these requirements?
Question23: A technician needs to implement a new VMware ESXi 5.5. environment. The customer has approximately four ESXi servers and is migrating 120 VMs from another environment to VMFS datastores created as Dell PS Series volumes. The technician needs to follow Dell best practice recommendations.How many VMFS datastore volumes should be created to store these VMs?
Question24: A technician is setting up a new M1000e blade environment that includes blade servers, switches, and a blade array (PSM4110E) in the blade chassis. The array is currently set up to use Fabric. The current configuration of the blade server, chassis, and switches is as follows:Switches A1/A2: M8024-k 10 GbE SwitchSwitches B1/B2: M8024-k 10 GbE SwitchSwitches C1/C2: Dell Ethernet Passthrough SwitchServer NIC A: 10 GbE NICServer NIC B: 10 GbE NICServer NIC C: 1 GbE NICM1000e CMC Version: 5.02M1000e Midplane Version: 1.0Which two actions should be taken to make sure that the blade servers and blade arrays can communicate? (Choose two.)
Question25: A technician sets up a new PS Series 6100XV array in an existing PS Group. The PS Group runs on a 10 GbE network with Data Center Bridging (DCB) enabled.What is the effect on the topology of the iSCSI network?
Question26: A customer must capture latency issues that occur for a very short duration.How does SAN HQ capture performance data with less than 60-second intervals?
Question27: Refer to the exhibit.An installer is adding a new 10 GbE array and switches into an existing 1 GbE environment. The existing 1 GbE switches are stacked. The installer needs to choose an uplink method.Which uplink method should the installer choose?
Question28: As part of failover testing, a technician restarts one of the two iSCSI switches between a single-member group and a single server. The two iSCSI switches are lagged together. After the technician restarts the switch, ping <arrayip> from the server fails to the array port IPs connected to the restarted switch.What is the most likely cause of the problem?
Question29: A customer is moving to a new datacenter and needs to put the existing two members into a new subnet.Each array has two iSCSI ports. The group does NOT use a dedicated management port.What is the correct sequence of steps to change all physical and group IPs on the members to the new subnet?
Question30: A customer has several datacenters on a small campus with full 10 GbE links between all datacenters. The customer needs to provide data protection to easily retrieve data in case of errors/deletions. The customer needs to protect data changes as quickly and often as possible to provide the greatest protection for recent changes.What is the simplest solution that meets ALL requirements?
Question31: A technician needs to add a new PS Series array to existing PS Series storage. Due to lack of switch ports, the technician does NOT connect the dedicated management ports on the new member. The technician has configured a dedicated management port on all existing members.Which two options provide a recommended solution? (Choose two.)
Question32: A customer has a single-member group with a RAID policy of RAID 6 in the default storage pool. A second member with a RAID policy of RAID 10 is added.What are two valid ways to add the second member? (Choose two.)
Question33: When does a VLAN ID need to be configured on Dell PS Series arrays?
Question34: An installer needs to deploy a PS series SAN and connect Susie Linux 11 SP2 hosts. The server is creating and deleting data frequently. The volumes on the PS Series SAN are thin provisioned.Which two options enable the PS Series array to reclaim space from the deleted data? (Choose two.)
Question35: A customer has a large complex VMware environment connected to a PS Series group. The group runs multiple arrays with two storage pools. The administrator notices performance and connection issues in the environment. After checking SAN HQ, the administrator notices the number of allowed connections has exceeded the maximum connections to the pool.Which three steps should be taken to fix this problem? (Choose three.)
Question36: A VMware administrator requests the creation of a 100 GB volume to use as a datastore on an ESX environment. The SAN administrator completes the request. For a few days, the VMware administrator is able to access and use the datastore. The VMware administrator then reports that the VM located on the datastore is greyed out and labelled as inaccessible.What are three possible reasons for this problem? (Choose three.)
Question37: An installer needs to set up a PS Series group using the recommended iSCSI network architecture.What is required for this setup?
Question38: A SQL administrator needs to deploy two databases: one for sales transactions and one for inventory.Which two topologies prevent a Torn Smart Copy from being created if one of them were restored with Auto Snapshot Manager? (Choose two.)
Question39: An installer sets up multiple volumes on a PS Series group and uses CHAP for access control. A host can NOT access the volume named TESTVOL. The host can see the volume target name in its iSCSI initiator and another server on the same subnet can access it.What is the probable cause of this issue?
Question40: A customer reports that a problematic array is acting up. The customer is able to open SAN HQ and provide a SAN HQ archive, but is unable to get to the Group manager GUI to initiate a diag log pull. The customer tries to use the Group IP address via FTP to retrieve previous diagnostic files, but that is also unsuccessful.What other option should the customer use to retrieve logs?
Question41: An administrator needs to change the RAID type from RAID 10 to either RAID 50 or RAID 6.What must the administrator select before Modify RAID Configuration within the Activities pane?
Question42: A technician has installed the Host Integration Toolkit (HIT/Microsoft) kit.Which two configurations should the technician set in Auto Snapshot Manager (ASM)? (Choose two.)
Question43: A new storage administrator (SA) is configuring replication on a newly created 1 TB volume. Management determines that asynchronous replication will be used.The new volume has 200 GB of used space.There is only 100 GB of space available on the DR group.Delegated space has only 50 GB of space still available.The SA looks at the delegated space on the DR group and determines that there is NOT enough room to fit the replica set for the new volume.Which action should the SA take at the DR site so that the new volume can be replicated?
Question44: An engineer needs to migrate a volume from a live production pool to a newly created pool, but is unable to do so.What must the engineer do before the migration can start?
Question45: A customer has an existing group with a single PS6210X member array configured as RAID 6. SAN HQ shows that the array is handling a very high level of IO. The database admin reports higher than normal latency for disk access. The same system ran in the past without problems for months, but it is gradually starting to get worse. The customer has allocated only 20% of the useable space on the array. The customer needs to improve performance with the LEAST impact on production.Which two options should the customer consider? (Choose two.)
Question46: A customer has a multi-member, multi-pool group in production. The load on the pools is NOT balanced.Which two methods should a SAN administrator use to balance the load between the pools? (Choose two.)
Question47: A customer needs 36 TB of storage space for an upcoming SAN implementation.Which two volume distributions are valid? (Choose two.)
Question48: An installer deploys a new environment that consists of a single hybrid array with a mix of SSDs and 10K disks. The installer initially connects several servers that run transactional data. The installer then migrates a large amount of file data to the new array. The servers perform very well for the first few hours. The performance then drops suddenly and significantly. The database administrator reports that the latency has suddenly increased beyond what was expected.What is the cause of the sudden drop in performance?